Custom Tea Packaging Bags for Wholesale Tea Brands

Tea Pouch Barrier Reports: How to Compare OTR and WVTR

Compare tea-pouch barrier reports only after matching the tested material, method, units and test conditions. Oxygen transmission rate (OTR) and water vapour transmission rate (WVTR) describe different properties. Neither a “high barrier” label nor a smaller number is enough to approve a packaging structure.

For an importer comparing several suppliers, the useful deliverable is a traceable report tied to the quoted pouch specification. Start by asking what was tested, rather than asking which quotation has the lowest headline value.

Keep oxygen and moisture measurements separate

OTR concerns oxygen passing through a material or package; WVTR concerns water vapour. AMETEK MOCON’s laboratory testing overview lists film OTR in cc/(m² × day) and film WVTR in g/(m² × day). It separately lists whole-package measurements in cc/day or g/day.

Those denominators matter. A value for a unit area of film is not automatically a value for one finished pouch. Ask the laboratory to explain the reporting basis before transferring a number into your purchasing specification.

Report field What to confirm before comparison
Measurement OTR or WVTR, with the complete result and any reporting qualifier.
Units Gas volume or water mass, area basis where applicable, and time basis.
Conditions Temperature, humidity conditions and relevant gas or pressure conditions.
Sample Material construction, thickness specification, sample identifier and film or finished-package scope.
Method Method designation, edition and any documented modification.

Normalise units without changing the meaning

For WVTR, 1 g/(m² × day) equals 1,000 mg/(m² × day). This is an exact mass-unit conversion, not a tea-pouch test result. A report expressed in milligrams may look numerically much larger while describing the same rate as one expressed in grams.

Do not stop at converting the numerator. Check whether the area and time bases also match. For oxygen results, retain any stated reference conditions for gas volume. If the reports use different conventions, ask the laboratory for a comparable presentation rather than silently editing the spreadsheet.

A method number is the beginning of the review

ASTM’s public scope for D3985-24 describes oxygen transmission measurement through film and related materials using a coulometric sensor. F1249-25 addresses water-vapour transmission through flexible barrier materials using a modulated infrared sensor.

Request the actual conditions and sample details alongside the method designation. Both ASTM summaries emphasise agreement between purchaser and seller on test conditions and acceptance arrangements. Two documents naming the same method should not be treated as directly comparable until those details have been checked.

If a report identifies a different method, do not automatically reject it. Ask the laboratory whether it suits the sample and whether its results can support the intended comparison.

Match the report to the material being purchased

Record the full proposed laminate specification and its revision. Ask whether the report represents that construction, a generic material family or a different thickness. Confirm the sample identifier and report date, then have the supplier identify any differences between the tested sample and the quotation.

Distinguish flat-film evidence from a completed-package evaluation. MOCON explains that package testing can include the walls, seals and closures. A film report should therefore remain labelled as film evidence; it should not quietly become a claim about every part of the finished tea pouch.

For separate questions about seals, see our seal strength and leak-testing guide. Permeation data and seal evaluation belong in different fields of the approval record.

Agree an acceptance specification for your tea project

Give the supplier the tea type, fill format, intended distribution conditions and required storage period. Ask your product-quality team to set the evidence needed for that project. This guide does not prescribe a universal OTR or WVTR limit for every tea.

ASTM D3985 also notes that OTR is one factor in packaging protection, rather than the sole determinant. Avoid translating a barrier number directly into a shelf-life promise without appropriate product and package evaluation.

  • Attach the approved material specification and report references to the order.
  • State OTR and WVTR requirements separately, including units and conditions.
  • Identify who approves the method, sampling and acceptance criteria.
  • Keep film and finished-package evidence clearly labelled.
  • Require review before substituting a different material construction.

Frequently asked questions

Is the lowest reported rate always the best choice?

Compare like-for-like reports first, then assess whether the material meets the project’s complete requirements.

Does a foil-looking pouch prove a barrier value?

No. Request the actual material specification and relevant evidence. Appearance does not provide a measured transmission rate.

Can barrier data prove a particular tea shelf life?

Not alone. Define the product, complete package and storage evaluation needed before making that claim.

Request a documented tea-packaging quote

Explore HEYI’s custom printed tea packaging bags, then send your tea-pouch requirements. Include any existing barrier specification and ask what supporting reports are available for the proposed construction.

Sources checked November 15, 2026. The unit conversion is arithmetic, not product test data; no HEYI barrier value or shelf-life guarantee is asserted.

Laisser un commentaire